Waste Heat Reuse from Liquid-Cooled Facilities in District Networks
Liquid cooling returns heat at 50 to 60 degrees Celsius, high enough to feed low-temperature district networks without heat pumps. We model supply and demand matching for 14 cities and find that a single 20 MW facility can cover the winter heating load of up to 9,000 homes. Seasonal mismatch is the binding constraint, not temperature.
Soil Moisture Memory and Heatwave Persistence
Dry soils amplify surface heating, but the length of this memory has been uncertain. Using a land-atmosphere coupled ensemble we show that a soil-moisture deficit in late spring extends the median heatwave by 2.3 days. The effect saturates once the root zone is depleted below a threshold fraction.