168 papers in twelve fields, 2011 to 2026. Search titles, authors, keywords and abstracts.
Results
Closed-Loop Stimulation Timed to Ongoing Oscillation Phase: A Model and Test
We derive the optimal delay for phase-locked stimulation under realistic latency and signal-to-noise constraints, and show that estimation error dominates the response beyond a few hundred milliseconds. In an animal preparation, stimulation timed to the predicted phase produced twice the entrainment of open-loop delivery.