Liquid-Cooled Rack Design for High-Density Compute Halls
We describe a direct-to-chip liquid cooling rack that removes forty kilowatts per rack at a facility power usage effectiveness below 1.15. Coolant distribution, leak containment and serviceability are treated as one design problem. Measurements from a pilot hall support a lumped thermal model of the loop.
Free-Cooling Economisers under Variable Humidity
Outside-air economisers save energy but are limited by humidity. We model the hours of free cooling available at a site as a function of an allowable humidity envelope and show how adiabatic assist extends them. A year of operating data from two halls confirms the predicted savings within five percent.
Chiller Plant Optimisation Using Receding-Horizon Control
Beatriz Quintanilla, Emeka Obi
We schedule chillers, pumps and cooling towers jointly with a receding-horizon controller that accounts for equipment staging costs. A mixed-integer formulation is relaxed to a form that solves within the control period. Deployed on a production plant, it reduced cooling energy by eleven percent.
Waste-Heat Recovery Loops for District Heating from Compute Halls
Beatriz Quintanilla, Tariq Al-Mansouri
We couple the return loop of a liquid-cooled hall to a district heating network through a heat pump with variable lift. A control strategy keeps the supply temperature within the network contract while following compute load. Over a heating season the loop delivered the equivalent of the winter demand of eight hundred homes.
Battery Energy Storage Sizing for Datacentre Ride-Through
We size battery storage for a datacentre by minimising lifetime cost subject to a ride-through requirement and a model of capacity fade. Outage statistics from the regional grid enter as a chance constraint. The resulting capacity is thirty percent below the usual worst-case rule at the same availability.
Model Predictive Control of Coupled Thermal Zones
We formulate cooling of thermally coupled zones as a receding-horizon problem whose model captures heat exchange between neighbouring halls. A distributed solver keeps the computation local to each zone with a bounded optimality loss. Closed-loop tests show a reduction in temperature variance relative to decentralised PID control.
Stability Margins for Controllers with Heavy-Tailed Disturbances
Classical stability margins assume bounded or Gaussian disturbances. Using an averaging result for systems driven by stable noise, we define a margin that is meaningful when disturbances have infinite variance and give a test for it. Case studies on a hovering platform and a cooling loop show that the usual margins overstate robustness.
Source Separation by Non-Negative Spectral Factorisation
We separate overlapping instruments in a mono recording by factorising its magnitude spectrogram under harmonicity and temporal-continuity constraints. The constraints remove the permutation ambiguity of unconstrained factorisation. Listening tests rate the separated stems above those of three baselines.
Beamforming for Crowded Acoustic Environments
We present a beamformer that maintains a target-speaker gain when many competing sources surround a microphone array. The design uses a sparsity prior on the source field and an alternating minimisation that converges in a few iterations. In a simulated arcade with forty talkers, intelligibility improved by six decibels over delay-and-sum.
Active Noise Cancellation in Server Halls
Fan noise in a server hall is broadband and varies with load. We combine a feedforward controller with a spectral estimate of the fan harmonics to attenuate tonal components by twelve decibels at the operator positions. Stability is guaranteed by a passivity condition on the secondary path.
Adaptive Impedance Control for Compliant Manipulators
We propose an impedance controller for manipulators with series elastic actuators that adapts to unknown payload and contact stiffness online. Lyapunov analysis establishes uniform boundedness of tracking and force errors. Experiments on a six-axis arm show stable contact with surfaces whose stiffness varies by two orders of magnitude.
Thermal Energy Storage for Free-Cooling Extension
We store coolant chilled by free cooling overnight in stratified tanks and discharge it through the warm part of the day, extending economiser hours at climates where they would otherwise run out. A scheduling model sizes the tank against the forecast. A demonstration hall achieved twenty-two percent more free-cooling hours than the same hall without storage.
Datacentre Thermal Control under Heavy-Tailed Load Surges
Tariq Al-Mansouri, Beatriz Quintanilla
Compute load in a datacentre arrives in surges whose size is heavy-tailed, and cooling controllers tuned for typical load overheat during rare spikes. We apply an averaged-dynamics model and the tail-aware stability margin to set cooling headroom, and test the design on two production halls. Peak inlet temperature excursions fall by sixty percent for a four percent rise in cooling energy.