Liquid-Cooled Rack Design for High-Density Compute Halls
We describe a direct-to-chip liquid cooling rack that removes forty kilowatts per rack at a facility power usage effectiveness below 1.15. Coolant distribution, leak containment and serviceability are treated as one design problem. Measurements from a pilot hall support a lumped thermal model of the loop.
Free-Cooling Economisers under Variable Humidity
Outside-air economisers save energy but are limited by humidity. We model the hours of free cooling available at a site as a function of an allowable humidity envelope and show how adiabatic assist extends them. A year of operating data from two halls confirms the predicted savings within five percent.
Chiller Plant Optimisation Using Receding-Horizon Control
Beatriz Quintanilla, Emeka Obi
We schedule chillers, pumps and cooling towers jointly with a receding-horizon controller that accounts for equipment staging costs. A mixed-integer formulation is relaxed to a form that solves within the control period. Deployed on a production plant, it reduced cooling energy by eleven percent.
Waste-Heat Recovery Loops for District Heating from Compute Halls
Beatriz Quintanilla, Tariq Al-Mansouri
We couple the return loop of a liquid-cooled hall to a district heating network through a heat pump with variable lift. A control strategy keeps the supply temperature within the network contract while following compute load. Over a heating season the loop delivered the equivalent of the winter demand of eight hundred homes.
Battery Energy Storage Sizing for Datacentre Ride-Through
We size battery storage for a datacentre by minimising lifetime cost subject to a ride-through requirement and a model of capacity fade. Outage statistics from the regional grid enter as a chance constraint. The resulting capacity is thirty percent below the usual worst-case rule at the same availability.
Ranked by r-index
Fields it trades citations with
Newest first
Thermal Energy Storage for Free-Cooling Extension
Datacentre Thermal Control under Heavy-Tailed Load Surges
Stability Margins for Controllers with Heavy-Tailed Disturbances
Waste-Heat Recovery Loops for District Heating from Compute Halls
Room Impulse Response Estimation with Learned Priors
Active Noise Cancellation in Server Halls
Battery Energy Storage Sizing for Datacentre Ride-Through
Source Separation by Non-Negative Spectral Factorisation
Beamforming for Crowded Acoustic Environments
Adaptive Impedance Control for Compliant Manipulators
Chiller Plant Optimisation Using Receding-Horizon Control
Model Predictive Control of Coupled Thermal Zones
Free-Cooling Economisers under Variable Humidity
Liquid-Cooled Rack Design for High-Density Compute Halls