Physics
Matter, energy and the models that connect the very small to the very large.
Papers per year
Every paper in Physics, counted by the year it appeared, 2011 to 2026.
The papers that travelled furthest
Two-Phase Immersion Cooling of Dense Compute Racks: A Transport Model
We derive a reduced transport model for two-phase immersion cooling of racks dissipating over 80 kW. The model couples bubble departure, vapour channelling between boards and condenser capacity, and predicts the onset of dry-out within 6 percent of bench measurements. It gives a rack-level design rule for board pitch as a function of power density.
Microchannel Flow Boiling Instability Thresholds
Parallel microchannels under flow boiling develop pressure-drop oscillations that couple to the supply loop. We map the stability boundary in the plane of heat flux and inlet subcooling and show that a modest inlet restriction suppresses the oscillation without a measurable pumping penalty. The thresholds collapse under a single dimensionless group.
Nucleate Boiling Heat Flux on Micro-Structured Copper Surfaces
We characterise pool boiling of a dielectric fluid on copper surfaces patterned with micro-pillar arrays of varying pitch. Critical heat flux rises by up to 70 percent over a smooth surface, and the gain collapses onto a single curve once the pillar pitch is scaled by the capillary length. A hydrodynamic model of vapour escape paths explains the optimum.
Floquet Prethermalization Lifetimes Beyond Linear Response
The heating time of a periodically driven many-body system grows exponentially with drive frequency, but the prefactor has resisted calculation. We obtain it for a family of spin chains by resumming the high-frequency expansion past linear response. The lifetime predictions agree with numerics at drive amplitudes where earlier bounds are vacuous.
Coolant Maldistribution in Parallel Cold Plates under Transient Load
When many cold plates share a manifold, a sudden load step redistributes flow in ways that steady-state design ignores. We derive a lumped-parameter model of the manifold-plate network and validate it against a 48-plate test loop. Flow to the most heavily loaded plate lags its heat demand by up to nine seconds, and a feed-forward valve schedule removes the lag.
Ranked by r-index
Fields it trades citations with
Newest first
Spinon Heat Transport in a Kagome Quantum Spin Liquid Candidate
Coolant Maldistribution in Parallel Cold Plates under Transient Load
Dissipative Time Crystals in Coupled Cavity Arrays
Heat Spreading in Graphene-Copper Laminates for Server Cold Plates
Microchannel Flow Boiling Instability Thresholds
Floquet Prethermalization Lifetimes Beyond Linear Response
Thermal Hall Response of Kagome Magnets
Two-Phase Immersion Cooling of Dense Compute Racks: A Transport Model
Many-Body Localization Transition in a Driven Lattice
Nucleate Boiling Heat Flux on Micro-Structured Copper Surfaces
Quantum Critical Scaling in a Layered Nickelate Analogue
Edge-Mode Localization in Disordered Topological Chains
Aging and Memory in Spin-Glass Films on a Kagome Substrate