Archive

168 papers in twelve fields, 2011 to 2026. Search titles, authors, keywords and abstracts.

Results

5 results

  1. Battery Energy Storage Sizing for Datacentre Ride-Through

    Tariq Al-Mansouri

    We size battery storage for a datacentre by minimising lifetime cost subject to a ride-through requirement and a model of capacity fade. Outage statistics from the regional grid enter as a chance constraint. The resulting capacity is thirty percent below the usual worst-case rule at the same availability.

    ENGJournal of RMH Engineering2019Cited by 3Resonance 3

  2. Datacentre Thermal Control under Heavy-Tailed Load Surges

    Tariq Al-Mansouri, Beatriz Quintanilla

    Compute load in a datacentre arrives in surges whose size is heavy-tailed, and cooling controllers tuned for typical load overheat during rare spikes. We apply an averaged-dynamics model and the tail-aware stability margin to set cooling headroom, and test the design on two production halls. Peak inlet temperature excursions fall by sixty percent for a four percent rise in cooling energy.

    ENGRMH Transactions on Control Systems2025Cited by 0Resonance 0

  3. Liquid-Cooled Rack Design for High-Density Compute Halls

    Beatriz Quintanilla

    We describe a direct-to-chip liquid cooling rack that removes forty kilowatts per rack at a facility power usage effectiveness below 1.15. Coolant distribution, leak containment and serviceability are treated as one design problem. Measurements from a pilot hall support a lumped thermal model of the loop.

    ENGJournal of RMH Engineering2011Cited by 7Resonance 8

  4. Waste-Heat Recovery Loops for District Heating from Compute Halls

    Beatriz Quintanilla, Tariq Al-Mansouri

    We couple the return loop of a liquid-cooled hall to a district heating network through a heat pump with variable lift. A control strategy keeps the supply temperature within the network contract while following compute load. Over a heating season the loop delivered the equivalent of the winter demand of eight hundred homes.

    ENGJournal of RMH Engineering2022Cited by 5Resonance 4

  5. Active Noise Cancellation in Server Halls

    Emeka Obi, Svetlana Marković

    Fan noise in a server hall is broadband and varies with load. We combine a feedforward controller with a spectral estimate of the fan harmonics to attenuate tonal components by twelve decibels at the operator positions. Stability is guaranteed by a passivity condition on the secondary path.

    ENGRMH Transactions on Acoustics and Signals2020Cited by 1Resonance 0