  1. Battery Energy Storage Sizing for Datacentre Ride-Through

    Tariq Al-Mansouri

    We size battery storage for a datacentre by minimising lifetime cost subject to a ride-through requirement and a model of capacity fade. Outage statistics from the regional grid enter as a chance constraint. The resulting capacity is thirty percent below the usual worst-case rule at the same availability.

    ENGJournal of RMH Engineering2019Cited by 3Resonance 3

  2. Thermal Energy Storage for Free-Cooling Extension

    Beatriz Quintanilla, Anh Tran

    We store coolant chilled by free cooling overnight in stratified tanks and discharge it through the warm part of the day, extending economiser hours at climates where they would otherwise run out. A scheduling model sizes the tank against the forecast. A demonstration hall achieved twenty-two percent more free-cooling hours than the same hall without storage.

    ENGJournal of RMH Engineering2026Cited by 0Resonance 0

  3. Free-Cooling Economisers under Variable Humidity

    Beatriz Quintanilla

    Outside-air economisers save energy but are limited by humidity. We model the hours of free cooling available at a site as a function of an allowable humidity envelope and show how adiabatic assist extends them. A year of operating data from two halls confirms the predicted savings within five percent.

    ENGJournal of RMH Engineering2013Cited by 7Resonance 6

  4. Chiller Plant Optimisation Using Receding-Horizon Control

    Beatriz Quintanilla, Emeka Obi

    We schedule chillers, pumps and cooling towers jointly with a receding-horizon controller that accounts for equipment staging costs. A mixed-integer formulation is relaxed to a form that solves within the control period. Deployed on a production plant, it reduced cooling energy by eleven percent.

    ENGJournal of RMH Engineering2015Cited by 4Resonance 5

  5. Datacentre Thermal Control under Heavy-Tailed Load Surges

    Tariq Al-Mansouri, Beatriz Quintanilla

    Compute load in a datacentre arrives in surges whose size is heavy-tailed, and cooling controllers tuned for typical load overheat during rare spikes. We apply an averaged-dynamics model and the tail-aware stability margin to set cooling headroom, and test the design on two production halls. Peak inlet temperature excursions fall by sixty percent for a four percent rise in cooling energy.

    ENGRMH Transactions on Control Systems2025Cited by 0Resonance 0