Liquid-Cooled Rack Design for High-Density Compute Halls
We describe a direct-to-chip liquid cooling rack that removes forty kilowatts per rack at a facility power usage effectiveness below 1.15. Coolant distribution, leak containment and serviceability are treated as one design problem. Measurements from a pilot hall support a lumped thermal model of the loop.
Free-Cooling Economisers under Variable Humidity
Outside-air economisers save energy but are limited by humidity. We model the hours of free cooling available at a site as a function of an allowable humidity envelope and show how adiabatic assist extends them. A year of operating data from two halls confirms the predicted savings within five percent.
Chiller Plant Optimisation Using Receding-Horizon Control
Beatriz Quintanilla, Emeka Obi
We schedule chillers, pumps and cooling towers jointly with a receding-horizon controller that accounts for equipment staging costs. A mixed-integer formulation is relaxed to a form that solves within the control period. Deployed on a production plant, it reduced cooling energy by eleven percent.
Waste-Heat Recovery Loops for District Heating from Compute Halls
Beatriz Quintanilla, Tariq Al-Mansouri
We couple the return loop of a liquid-cooled hall to a district heating network through a heat pump with variable lift. A control strategy keeps the supply temperature within the network contract while following compute load. Over a heating season the loop delivered the equivalent of the winter demand of eight hundred homes.
Thermal Energy Storage for Free-Cooling Extension
We store coolant chilled by free cooling overnight in stratified tanks and discharge it through the warm part of the day, extending economiser hours at climates where they would otherwise run out. A scheduling model sizes the tank against the forecast. A demonstration hall achieved twenty-two percent more free-cooling hours than the same hall without storage.
Datacentre Thermal Control under Heavy-Tailed Load Surges
Tariq Al-Mansouri, Beatriz Quintanilla
Compute load in a datacentre arrives in surges whose size is heavy-tailed, and cooling controllers tuned for typical load overheat during rare spikes. We apply an averaged-dynamics model and the tail-aware stability margin to set cooling headroom, and test the design on two production halls. Peak inlet temperature excursions fall by sixty percent for a four percent rise in cooling energy.