Archive
168 papers in twelve fields, 2011 to 2026. Search titles, authors, keywords and abstracts.
Results
Waste-Heat Recovery Loops for District Heating from Compute Halls
Beatriz Quintanilla, Tariq Al-Mansouri
We couple the return loop of a liquid-cooled hall to a district heating network through a heat pump with variable lift. A control strategy keeps the supply temperature within the network contract while following compute load. Over a heating season the loop delivered the equivalent of the winter demand of eight hundred homes.
Floquet Prethermalization Lifetimes Beyond Linear Response
The heating time of a periodically driven many-body system grows exponentially with drive frequency, but the prefactor has resisted calculation. We obtain it for a family of spin chains by resumming the high-frequency expansion past linear response. The lifetime predictions agree with numerics at drive amplitudes where earlier bounds are vacuous.
Waste Heat Reuse from Liquid-Cooled Facilities in District Networks
Liquid cooling returns heat at 50 to 60 degrees Celsius, high enough to feed low-temperature district networks without heat pumps. We model supply and demand matching for 14 cities and find that a single 20 MW facility can cover the winter heating load of up to 9,000 homes. Seasonal mismatch is the binding constraint, not temperature.
Soil Moisture Memory and Heatwave Persistence
Dry soils amplify surface heating, but the length of this memory has been uncertain. Using a land-atmosphere coupled ensemble we show that a soil-moisture deficit in late spring extends the median heatwave by 2.3 days. The effect saturates once the root zone is depleted below a threshold fraction.