Archive
168 papers in twelve fields, 2011 to 2026. Search titles, authors, keywords and abstracts.
Results
Waste-Heat Recovery Loops for District Heating from Compute Halls
Beatriz Quintanilla, Tariq Al-Mansouri
We couple the return loop of a liquid-cooled hall to a district heating network through a heat pump with variable lift. A control strategy keeps the supply temperature within the network contract while following compute load. Over a heating season the loop delivered the equivalent of the winter demand of eight hundred homes.
Free-Cooling Hours Under Shifting Humid-Heat Regimes
We project the annual number of hours in which outside air or water can reject facility heat without mechanical chilling, for 220 sites to 2060. Humid-heat extremes erode free-cooling hours faster than mean warming suggests, and fluids with higher operating temperatures preserve most of the margin. Coolant stability under thermal cycling is a limiting factor in the warmest regimes.
Waste Heat Reuse from Liquid-Cooled Facilities in District Networks
Liquid cooling returns heat at 50 to 60 degrees Celsius, high enough to feed low-temperature district networks without heat pumps. We model supply and demand matching for 14 cities and find that a single 20 MW facility can cover the winter heating load of up to 9,000 homes. Seasonal mismatch is the binding constraint, not temperature.
Heat Spreading in Graphene-Copper Laminates for Server Cold Plates
Graphene-copper laminates spread heat anisotropically, and we show how to exploit this in cold plates over processors with strongly non-uniform dissipation. A conduction model with interfacial resistance predicts peak junction temperature to within 1.5 K. A 40 percent reduction in hot-spot temperature rise is obtained with a 12 percent mass penalty.
Spinon Heat Transport in a Kagome Quantum Spin Liquid Candidate
We measure the low-temperature thermal conductivity of a kagome quantum spin liquid candidate down to 40 mK and find a residual linear term consistent with itinerant gapless excitations. The magnitude is sensitive to sample disorder in a way not seen in the thermal Hall channel. We discuss implications for the spinon Fermi-surface scenario.
Non-Flammable Dielectric Coolants from Fluorinated Ethers
Anahita Farahmand, Mei-Ling Zhou
We synthesise a family of partially fluorinated ethers with boiling points tuned between 45 and 70 degrees Celsius for two-phase immersion cooling. The best candidate combines a latent heat of 110 kJ per kilogram, no measurable flash point and low global warming potential. Heat transfer on structured copper surfaces matches that of established coolants.
Siting Large Thermal Loads Against Regional Climate Risk
Large facilities that reject megawatts of heat are exposed to the regional climate for decades. We build a siting framework that scores locations on projected wet-bulb extremes, water availability and seismic hazard, and apply it to 220 candidate sites. Liquid and immersion cooling shift the preferred sites toward hotter, drier regions that would be ruled out under evaporative cooling.
Coolant Maldistribution in Parallel Cold Plates under Transient Load
When many cold plates share a manifold, a sudden load step redistributes flow in ways that steady-state design ignores. We derive a lumped-parameter model of the manifold-plate network and validate it against a 48-plate test loop. Flow to the most heavily loaded plate lags its heat demand by up to nine seconds, and a feed-forward valve schedule removes the lag.